This connection type implements the remote control protocol for the DHD RM2200D.
Supported Devices and Prerequisites
This protocol supports the DHD RM2200D. Communication is through TCP, so the DSP core must be connected with the network.
Configuration
On the General tab, enter the IP address and the TCP port for the remote control protocol (usually 2200).
Parameters
This connection type provides the following parameters:
Main Control Unit
main/button/<button>
(boolean, read-only) - the press state of the respective button on the main control unitmain/lcd/1
andmain/lcd/2
(string, read-only) - the texts currently displayed in the two-line LCD of the main control unit
Faders
Fader numbers are 1
through 16
.
fader/<number>/source
(integer, read/write) - the ID of the audio source currently assigned to this faderfader/<number>/on
(boolean, read/write) - the status of the fader ON functionfader/<number>/cue
(boolean, read/write) - the status of the fader CUE functionfader/<number>/button/<button>
(boolean, read-only) - the press state of the respective button on this fader stripfader/<number>/led/<led>
(boolean, read-only) - the state of the respective LED on this fader stripfader/<number>/status/<status>
(boolean, read-only) - theinputstate
,timer
,faderstart
andloadsetup
state of this fader strip